Home/Services/High power
⌁ High-power & high-current

Boards that won’t melt.

Up to 200 A continuous. Heavy copper, IMS and aluminum-core, bus-bar attach, GaN/SiC. Every high-power board ships with a TRM thermal report — because “looks fine” isn’t a spec.

200 Acontinuous handled
3 oz +copper / IMS
±3 °Csim vs. measured
GaN/SiCtopologies
⌁ What you get

The deliverables.

01

Current-carrying layout

Copper-weight and pour geometry sized to IPC-2152 with real margin — validated, not chart-guessed.

02

TRM thermal report

Steady-state + transient thermal of the whole board at worst-case ambient. Named deliverable, every time.

03

PDN + IR-drop

Voltage-drop analysis across the power path so the rail still regulates at full load.

04

Mechanical + thermal interface

Heat-sink, cold-plate, and bus-bar attach detailed for assembly, with TIM and torque callouts.

⌁ Power technologies

What we’ve built.

Topologies

  • Buck / boost / buck-boost
  • LLC + phase-shift full bridge
  • GaN + SiC half/full bridge
  • Multiphase VRM
  • PoE / PoE++ injectors

Construction

  • 2–4 oz heavy copper
  • IMS / aluminum-core MCPCB
  • Bus-bar + busbar-on-board
  • Embedded copper coins
  • Thick-film + AlN substrates

Applications

  • EV onboard chargers + DC-DC
  • Industrial motor drives
  • Telecom rectifiers
  • Battery management (BMS)
  • Solar / energy storage
⌁ Sample engagement

120 A EV buck stage, re-spun before the melt.

The brief

An EV onboard charger’s 120 A buck stage was running hot in NPI. The customer wanted to know if 2 oz copper plus heatsinks would survive a Phoenix summer.

What we found

  • TRM predicted 96 °C on the inductor pad at 2 oz / 55 °C ambient — over the cap.
  • The VRM-to-inductor copper necked down at a routing channel, creating a current bottleneck.
  • No thermal relief plan for the high-side FET to the chassis.

Outcome

Re-spec’d to 3 oz copper, widened the bottleneck 60%, added a copper coin under the FET. TRM dropped the hotspot to 82 °C; bench measured 79 °C. Saved an NPI re-spin.

⌁ FAQ

Common questions.

Do you guarantee the thermal numbers?

We deliver a TRM simulation correlated to within ~3 °C of bench measurement on past boards. It’s an engineering estimate with stated assumptions, not a warranty — but it’s the same tool that’s caught real melt-downs pre-fab. See PhySignoff.

Heavy copper or IMS — which?

Depends on power density and mechanical needs. We’ll model both in TRM and show you the tradeoff in the quote.

Can you do the magnetics layout too?

Yes — planar magnetics, custom inductor footprints, and winding-on-PCB are in scope.

Prove it won’t melt.

Every high-power board ships with a TRM thermal report. Fixed-fee band in 60 seconds.